waste incinerator wet scrubber system

Clover supply optional dust wet scrubber system for waste incinerators. the main parts included wet cooling spray scrubber, wet dust filter and fog&waste separator.


Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
Key Features:
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. 
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day.
* PLC Control Plane for Intelligent operation. 
* New Design for pet animal cremation business.

* One year warranty on incinerator and parts in stock.
WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

DAILY AVERAGE VALUES :
Total dust: 10 mg/m3 Carbon  monoxide: 50 mg/m3
Gaseous and vaporous organic substances, expressed as total organic carbon: 10 mg/m3 Hydrogen Chloride: 10 mg/m3
Hydrogen fluoride: 1 mg/m3 Sulphur dioxide: 50 mg/m3
Nitrogen monoxide and nitrogen dioxide, expressed as nitrogen dioxide: 200 mg/m3

10-MINUTE AVERAGE VALUE:
Carbon monoxide: 95% – 150 mg/m3

HALF-HOURLY AVERAGE VALUES:
Total dust: 100% ? 30 mg/m3, 97% – 10 mg/m3
Carbon monoxide: 100% – 100 mg/m3
Gaseous and vaporous organic substances, expressed as total organic carbon: 100%  ?20 mg/m3, 97 % ?  10 mg/m3
Hydrogen chloride: 100% – 60 mg/m3, 97% – 1O mg/m3 Hydrogen fluoride: 100% – 4 mg/m3, 97% –
2  mg/m3
Sulfur dioxide: 100% – 200 mg/m3, 97% ? 50 mg/m3
Nitrogen monoxide and nitrogen dioxide, expressed as nitrogen dioxide 100%  – 400 mg/m3, 97% – 200 mg/m3

AVERAGE VALUES OVER A SAMPLJNG PERIOD >6 HOURS TO 8 HOUAS:
Dioxins and furans: 0.1 ng l TE0/Nm3
 

AVERAGE VALUES OVER A SAMPLING PERIOD >30 MINUTES TO 8 HOURS:
Cadmium and its compounds: Total 0.05 mg/m3 Thallium and its compounds : Total 0.05 mg/m3 Mercury and its compounds: 0.05 mg/m3 Antimony and its compounds: Total 0.05 mg/m3 Arsenic and its compounds: Total 0.05 mg/m3 Lead and its compounds : Total 0.05 mg/m3 Chromium and its compounds: Total 0.05 mg/m3 Cobalt and its compounds: Total 0.05 mg/m3 Copper and its compounds: Total 0.05 mg/m3 Manganese and its compounds: Total 0.05 mg/m3 Nickel and its compounds: Total 0.05 mg/m3 Vanadium and its compounds: Total 0.05 mg/m3
Standard conditions defined as T = 273°K, P= 101.3 kPa, 11% 02, dry gas
Third Party Test Results: A copy of test results from stack sampling and analysis of air emissions from an incinerator of the same modal and capacity burning typical medical waste shall be provided and in compliance with EU DIAECTIVE 2000/76/EC. The tests shall be conducted by an independent Third Party duly accredited and certified. The test report shall
include concentrations of 17 congeners of 2,3,7,8-TCOO/F, corresponding detection limits, Toxic Equivalent (TEQ) using 1-TEF as well as TEQ from non-detected congeners and the maximum possible TEQ (estimated maximum possible concentration/upper bound). sampling standard recoveries, extraction standard recoveries, and other quality assurance/quality control information
Stack (chimney). The stack shall have a minimum height of 3.0 meters above ground level

Emergency bypass: The emergency bypass shall remain closed and should not permit the release of gaseous emissions during normal operations. The date, time and duration of the

opening of the emergency bypass during abnormal conditions should be recorded and included in the permanent record

Bottom ash handling: The incinerator should include a wet ash sump with additional means to prevent bottom ash from being released into the workspace

Painting and finishing: The inner surfaces of the outer casing of the incinerator, the exterior surfaces of the outer casing, the control panel, and piping, except corrosion-resistant steel, should be cleaned to the base metal for removal of eil and rust before primer is applied. A weather resistant finish should be placed on all items that will be exposed to the  outside

Recording: Recording of operating parameters should be able to be done digital or analog and  should include values sufficient to confirm that cycle parameters have been achieved and maintained within the manufacturer’s specified tolerances. Printed records should be readable for not less than 2 years
Typical service life 10 years
Spare parts Suitable for one year of operation
Languages of Operating and service manual English and French language