Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime.
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day.
* PLC Control Plane for Intelligent operation.
* New Design for pet animal cremation business.

Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity(Average) | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
DAILY AVERAGE VALUES :
Total dust: 10 mg/m3 Carbon monoxide: 50 mg/m3
Gaseous and vaporous organic substances, expressed as total organic carbon: 10 mg/m3 Hydrogen Chloride: 10 mg/m3
Hydrogen fluoride: 1 mg/m3 Sulphur dioxide: 50 mg/m3
Nitrogen monoxide and nitrogen dioxide, expressed as nitrogen dioxide: 200 mg/m3
10-MINUTE AVERAGE VALUE:
Carbon monoxide: 95% – 150 mg/m3
HALF-HOURLY AVERAGE VALUES:
Total dust: 100% ? 30 mg/m3, 97% – 10 mg/m3
Carbon monoxide: 100% – 100 mg/m3
Gaseous and vaporous organic substances, expressed as total organic carbon: 100% ?20 mg/m3, 97 % ? 10 mg/m3
Hydrogen chloride: 100% – 60 mg/m3, 97% – 1O mg/m3 Hydrogen fluoride: 100% – 4 mg/m3, 97% –
2 mg/m3
Sulfur dioxide: 100% – 200 mg/m3, 97% ? 50 mg/m3
Nitrogen monoxide and nitrogen dioxide, expressed as nitrogen dioxide 100% – 400 mg/m3, 97% – 200 mg/m3
AVERAGE VALUES OVER A SAMPLJNG PERIOD >6 HOURS TO 8 HOUAS:
Dioxins and furans: 0.1 ng l TE0/Nm3
AVERAGE VALUES OVER A SAMPLING PERIOD >30 MINUTES TO 8 HOURS:
Cadmium and its compounds: Total 0.05 mg/m3 Thallium and its compounds : Total 0.05 mg/m3 Mercury and its compounds: 0.05 mg/m3 Antimony and its compounds: Total 0.05 mg/m3 Arsenic and its compounds: Total 0.05 mg/m3 Lead and its compounds : Total 0.05 mg/m3 Chromium and its compounds: Total 0.05 mg/m3 Cobalt and its compounds: Total 0.05 mg/m3 Copper and its compounds: Total 0.05 mg/m3 Manganese and its compounds: Total 0.05 mg/m3 Nickel and its compounds: Total 0.05 mg/m3 Vanadium and its compounds: Total 0.05 mg/m3
Standard conditions defined as T = 273°K, P= 101.3 kPa, 11% 02, dry gas
Third Party Test Results: A copy of test results from stack sampling and analysis of air emissions from an incinerator of the same modal and capacity burning typical medical waste shall be provided and in compliance with EU DIAECTIVE 2000/76/EC. The tests shall be conducted by an independent Third Party duly accredited and certified. The test report shall
include concentrations of 17 congeners of 2,3,7,8-TCOO/F, corresponding detection limits, Toxic Equivalent (TEQ) using 1-TEF as well as TEQ from non-detected congeners and the maximum possible TEQ (estimated maximum possible concentration/upper bound). sampling standard recoveries, extraction standard recoveries, and other quality assurance/quality control information
Stack (chimney). The stack shall have a minimum height of 3.0 meters above ground level
Emergency bypass: The emergency bypass shall remain closed and should not permit the release of gaseous emissions during normal operations. The date, time and duration of the
opening of the emergency bypass during abnormal conditions should be recorded and included in the permanent record
Bottom ash handling: The incinerator should include a wet ash sump with additional means to prevent bottom ash from being released into the workspace
Painting and finishing: The inner surfaces of the outer casing of the incinerator, the exterior surfaces of the outer casing, the control panel, and piping, except corrosion-resistant steel, should be cleaned to the base metal for removal of eil and rust before primer is applied. A weather resistant finish should be placed on all items that will be exposed to the outside
Recording: Recording of operating parameters should be able to be done digital or analog and should include values sufficient to confirm that cycle parameters have been achieved and maintained within the manufacturer’s specified tolerances. Printed records should be readable for not less than 2 years
Typical service life 10 years
Spare parts Suitable for one year of operation
Languages of Operating and service manual English and French language