Waste Incinerators

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)

Clover supply optional dust wet scrubber system for waste incinerators. the main parts included wet cooling spray scrubber, wet dust filter and fog&waste separator. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. Key Features: * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime.  * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. * PLC Control Plane for Intelligent operation.  * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour […]
Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube. Model SYC19, Price: $110usd/set, MOQ: 5 sets. EXW factory term(donot including shipping cost) Purchase email:  info@hiclover.com 1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency […]
Average loading capacity of 1,000 kg/day with maximum loading capacity of 1,200 kg. Nominal burning rate shall be 100 -140 kg/hr with 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading.Primary power source shall be electricity but capable of using diesel fuel as a supplemental fuel.The waste incinerators shall be designed for 3 Phase, 380-400 V, 50 Hz electricity supply.Should have dual combustion chambers with gas temperature achieve 1000 C for retention time at least 2 second,Have a thermal efficiency of not less than 85%.All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion.The incinerator combustion chambers should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion, etc.Primary and secondary chambers preferably have rounded inside corners to avoid the formation of dead zone or cold pockets. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201   Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com  
diesel oil burner for incinerators WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   The incinerator burn waste in primary combustion chamber and burn the smoke from primary  combustion chamber again to make sure environmentally friendly with no black smoke,  smelless, reduce pathogenic bacteria infection. System solutions for medical waste environmental, including waste incineration, smoke  emission treatment, high-temperature […]
HICLOVER Top Feeding Door Waste Incinerators ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or  3 sections) ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORSMedical Waste Incinerator, 100 to 120 Kg/hrApplication   For incineration, general and pathologicalCapacity    100 C 120 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%Construction Constructed from heavy duty mild or aluminized  steelOr equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings    ProvidedLoading Manual loading of wastePrimary Burner                        Fully automatic, with fuel, temperature and speed  controls with ignition system  flame detector                                                         Air fan Complete with safety features, flame failure                                                                    Diesel fired fuel injector type                                               Flange mountedBlower   Provided.  3 phase for supplying excess combustion air through the distribution system with speed control systemTemperature Minimum exit 850 0CObservation port To be provided with protective glass type     3.3    Secondary chamber
2.) Size requirement for the incinerators is 750 — 850 kg capacity 3.) The bum rate should be 80 LL 100 kg/ hour. 4) The primary chamber shouId have an operating temperature of 900 -1200 degree C.5) The incinerator should hate a high temperature secondary chamber and 2 second gasretention time at 850- 1150 degree C so that it is suitable for high risk materials. 6). The incinerator should have temperature monitoring and thermostat control for ease ofoperation and assurance of bum temperature to confirm correct operation. 7). The incinerator should be capable of burning any of the hazardous wastes listed in thesubsequent section. 8) The incinerator should be capable of burning diesel oil and should include a larger fueltank (10-500 litres) and generator (3 –40 kV) set that can be carried on the trailer with theincinerator so that the unit requires no external electrical power supply. 9.) The incinerator should be trailer mounted so that it is a po 21. The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing. 22. Process Filtering system: Scruber to be mentionned as optional 23. Emission Standards Compliance: BS 3316 or équivalent standard 23. Capacity to treat […]
  Items/Model TS1000 Picture   Principle Solid Waste Incineration Treatment Burn Rate Average 1000kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 8.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes […]
Baltur Burner BT14GW for waste incinerator spare parts oil burner,  almost for incinerator capacity 50/100/150kgs per hour. 7.5-14.5kgs per hour diesel oil fuel 0.13Kw 16kgs per set Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. […]
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORSMedical Waste Incinerator, 100 to 120 Kg/hrApplication   For incineration, general and pathologicalCapacity    100 C 120 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%Construction Constructed from heavy duty mild or aluminized  steelOr equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings    ProvidedLoading Manual loading of wastePrimary Burner                        Fully automatic, with fuel, temperature and speed  controls with ignition system  flame detector                                                         Air fan Complete with safety features, flame failure                                                                    Diesel fired fuel injector type                                               Flange mountedBlower   Provided.  3 phase for supplying excess combustion air through the distribution system with speed control systemTemperature Minimum exit 850 0CObservation port To be provided with protective glass type     3.3    Secondary chamber
Open chat
Scan the code
Hello 👋
Can we help you?